国外港口PSC检查的重点和趋势(二)——巴黎备忘录地区


自疫情爆发以来,为了降低疫情扩散风险,保护海员、港口国检查官和其他相关人员的个人安全,同时最大化的维持船舶正常营运,国际海事组织和各个备忘录地区陆续发布应对措施。例如,东京备忘录于2021年3月1日发布了应对Covid-19的临时指南;从2021年4月1日起启动远程PSC检查等,这些措施不断影响着港口国监督检查的开展。          

近日,KR船级社统计了2021年第一季度港口国监督检查情况,它体现了各个国家/地区港口国监督检查的重点和趋势。那么对于巴黎备忘录地区,上一季度PSC检查的情况如何?今后检查的重点又是什么?

01Detainable deficiencies

2021年第一季度,巴黎备忘录地区不论是船舶滞留艘次,还是滞留率都明显增加,导致滞留缺陷如下:

(1)FIRE SAETY

Fire Dampers of E/R supplier fans not workings & duct distortion

Emergency fire pump found inoperative during test

A-class fire door in galley fixed to open

Water mist system defective

Some fire doors defective and not closed completely

Several self-closing valves for sounding pipes and for level indicators blocked in open position

Oil leakage from main engine oil cooler through damaged gaskets

Main fire line on main deck inoperative (frozen)

Full of oil mixture in engine room bilge well

(2)ISM

ISM detainable deficiency on the basis of many deficiencies

Crew unfamiliar with operation of machinery and position of equipment on board

Crew not familiar with RADAR operation and emergency steering

Inappropriate implementation of enclosed space procedures

SMS implementation failure

No records of lifeboat operation

(3)MLC(Working and Living Condition)

Accommodation heating systems

Toilets flushing system in the accommodation not working correctly

Accommodation not in cleanliness

All crew members' wages not paid in full and at monthly intervals

Total lack of fresh vegetables and fruit.

SEA expired, over maximum period of shipboard service for seafarers

(4)Life Saving Appliances

Lifeboat Engine not starting

Lifeboats not lowered and maneuvered into the water

Rescue boat and life raft defective

Rescue boat launching davit hydraulic leaks and pressure gauge inoperative

(5)Pollution Prevention

Sewage treatment plant not working properly

Deck full of oil pollution hazards

Insufficient procedure for changeover when entering SECA

Eng. Room Bilge High water level alarm inoperative

Oily Water Separator inoperative and found some leakage

Full of Residual tank & bilge collecting tank

(6)ILL

Side shell crack

Manhole from engine room to bilge keel space in open

Hatch coaming bracket crack

Natural ventilator (mushroom type) holed and patched temporally, Gooseneck air vent closing devices missing

Hatch cover cleat missing

(7)Certificate and Documentation

Civil liability for bunker oil pollution damage certification is not valid (Only photocopy)  

Flag endorsement missing for 2/O, 3/O and C/E

Medical certificate expired

Captain not holding GOC

No SMC on board

(8)Safety of Navigation

Several navigation lights damaged and inoperative

ECDIS not in use up to date

MF/HF and VHF DSC not operational

No charts and nautical publications available

Bridge found one window of different thickness

02Items to be inspected thoroughly

在巴黎备忘录地区,PSCO会对以下项目开展全面的检查,以核实是否满足相关要求

(1)FIRE SAETY

Operation of em’cy fire pump and leak check

Function and contact condition of E/R funnel damper

Condition of Fireman’s outfit

Closing condition of A-class fire door

Fire doors in normal operation

Installation of insulation for heat surface

Enough ventilation of cargo holds before entering a port

Check operation of water mist system

Check of breathing apparatus and its attachment

Self-closing valves for sounding pipes and for level indicators

Operation and maintenance of main engine oil cooler

Sprinkler nozzles in normal working condition without blockage of deposits in the nozzles

(2)ISM

Implementation of Fire and Abandon ship Drill and record

Black out test (simulation test) and crews’ familiarity with it

Crews’ familiarity with the operation of CO2 system

PSCO emphasizes implementation of ISM and checks real-time NIR database

Drill records for emergency response

SMS on board properly implemented

Crew familiarization with machinery and position of equipment on board

Correspondence and familiarization of SOLAS training manual and equipment on board

Check effectiveness of emergency drills and familiarity related to responsible equipment and system

Crew familiarization with lifeboat operation

Compliance of procedures for enclosed space entry

Check compliance of COLREG of duty officers

(3)MLC(Working and Living Condition)

Crews protection 

Crew’s including captain and C/E working hour and resting hour record

Toilet operation in accommodation

Accommodation cleanness

Wages paid regularly and in full accordance with SEA

(4)Life Saving Appliances

Immediate start of em’cy equipment under very cold weather

Magnetic compass in lifeboat

Hydraulic system in launching appliance for rescue boat

Condition of rescue boat and liferaft

Navigation and radio equipment in good working condition for immediate use

EEBDs with sufficient air pressure and good working condition

(5)Pollution Prevention

Operation of sewage treatment plant

Inspection related to SOx emission

Operation of quick closing valve

Control of garbage

Procedures for fuel changeover when entering SECA

Function of oily water separator and 15ppm alarm check 

High water level alarm

Hatch cover hydraulic cylinder in good working condition

OWS in proper working condition

(6)ILL

Condition of structure

Function of water ingress system and de-watering system

Manhole properly secured, closed

(7)Safety of Navigation

VDR function and random alarm test and normal condition check after reset

Navigation plan and up-to-date notice to mariner, chart and publication

Function of GMDSS and familiarity with GMDSS equipment

Check condition of navigation lights

Check ECDIS/ENC in use up to date